Single Packaged Gas/Electric Units, 14 SEER, R-410A, 81% AFUE, 2 Ton thru 5 Ton Units

The R8GE Series single phase, packaged gas/electrics are high efficiency self-contained cooling units that can be installed on a roof or on a slab. The convertible unit design makes installations simple in all applications. Units are ETL and ETLc listed.
 

Heating Range ( MBH )

Cooling Range ( MBH )

Airflow Range ( CFM )

Heating Efficiency at full load ( AFUE )

Cooling Efficiency ( EER )

Standard Features:

  • Quality, state-of-the-art Copeland scroll compressor
  • Proven, industry standard components for easier service and availability
  • High and low pressure switch  for added compressor protection
  • Micro-Channel coils: both indoor and outdoor, all aluminum coils are designed to optimize heat transfer, minimize size and cost, and increase durability and reliability
  • Liquid line filter driers are factory installed at a convenint location for service
  • Externally accessible service ports for quick access to refrigerant system without disruption operation
  • Compact footprint/low profile means the unit is easier to handle and transport
  • Heavy-gauge full perimeter base rails facilitate forklift handling and curb mounting
  • Convertible air delivery: horizontal or downflow to accomodate rooftop or horizontal application
  • Galvanized steel cabinet with polyurethane finish provides 950 hour salt spray protection to resist corrosion
  • Wire guard coated with earth friendly epoxy and mesh hail guard will never rust and protect hte coil from being damage by lawnmowers, hail, etc
  • Access to controls and major components in easy in-and-out service areas
  • Low voltage trasformer includes a 3 Amp fuse to protect low voltage circuit
  • Corrosion-resistant drain pan quickly drains away evaporator condensate
  • One piece top for great fit and finish plus total seal: well designed, quality construction. Drip edge on top panels whisks away rainwater. Embossed bottom pan keeps blower component compartment dry.
  • Quiet operation: low vibration, 20" fan blade combinded with custom venturi condenser fan
  • SmartLife® control board provides extended life to igniters using hot surface ignition technology. programmed to learn the heat-up characteristics of the igniter, then adapt the ignition time to the characteristics of the furnace so the igniter is energized appropriately
  • Hot surface igniter: innovative appliation of an appliance type igniter with a 20 year history of reliability

Optional Features - Factory Installed

  • Low NOX
  • Gas heating section

Optional Features - Field Installed

  • Roof curb (8", 14", 18" or 24")
  • Cap, duct adapter
  • Supply/return transition
  • Concentric diffuser
  • Manual or motorized fresh air damper
  • Economizer
  • Power exhaust
  • Filter kit
  • Hood type hail guard
  • Smoke detector
  • Multi signal control
  • Low ambient kit
  • Propane/high altitude conversion kit
  • Outdoor thermostat
  • Universal hard start kit
  • Freezestat
  • CO2 control sensor

Brochures
3 Files

Brochures


English
Light Commercial Marketing Catalog
Light Commercial HVAC Equiment Marketing Catalog
Download File
1.0 MB
Brochure - Smoke Detector - Light Commercial
Brochure about smoke detectors available for Models P6SD, R6GP, Q6SD, R8GD, R6GN, R6GD, B5SM, & Q6SP 
Download File
158.2 kB
Heating, Cooling, Ventilation & VRF Product Line
Heating, Cooling, Ventilation & VRF Product Line Sheet
Download File
630.7 kB

Technical Data
2 Files

Technical Data


English
Tech Spec - R8GE 1ph
Description, options, dimensions for Model R8GE
Download File
1,021.5 kB
Tech Spec - R8GE - 3ph
Description, options, accessories and dimensions for Model R8GE, 3 phase unit.
Download File
559.1 kB

Service/Installation
21 Files

Service/Installation


English
Unit Installation Manual - Model R8GE
Installation manual for Model R8GE
Download File
3.0 MB
Option - Installation - Economizer - Light Commercial
Modulating economizer, downflow with filter installation instructions for Models R6GD, Q6SD, P6SD, R6GF, & R8GD
Download File
2.1 MB
Option - Installation - Manual Fresh Air Damper - Light Commerical
Manual fresh air damper installation instructions for Models P6SD, Q6SD, R6GD, R6GI, & R8GD
Download File
115.5 kB
Option - Installation - Supply/Return Transition - Light Commercial
Supply/return (16" & 18") transition installation instructions for Models P6SD, R6GI, Q6SD, R6GD, & R8GD
Download File
69.0 kB
Option - Installation - Motorized Fresh Air Damper - Light Commercial
Motorized fresh air damper installation instructions  for Models P6SD, Q6SD, R6GD, R6GI, & R8GD
Download File
139.0 kB
Option - Installation - Hood Hail Guard - Light Commercial
Hood type hail guard installation instructions for Models Q6SD, P6SD, R6GD, R8GD, & R6GI
Download File
579.0 kB
Option - Installation - Filter Kit - Light Commercial
Filter kit installation manual for for Models R8GD, P6SD, DF6SF, R6GF, & R8GD
Download File
323.0 kB
Option - Installation - Outdoor Thermostat - Light Commercial
Outdoor thermostat kit installation instruction for Models JT4BD, P6SD, Q6SD, R6GD, & R8GD
Download File
9.9 kB
Option - Installation - Hard Start - Light Commercial
Universal hard start kit installation instructions for Models JS4BD, JT4BD, P6SD, DF6SF, R8GD, R6GF, R8HE
Download File
263.4 kB
Option - Installation - Power Exhaust - Lt Commercial
Power exhaust (horizontal/vertical) kit installation manual for Models R8GD, P6SD, R6GF, Q6SD, & R6GD
Download File
505.4 kB
Option - Roof Curb Installation - Lt Commercial Hi Eff
Roof curb installation manual for light commercial Models P6SD, P8SE, Q6SD, R6GD, R8GE, R8HE
Download File
174.1 kB
Option - Installation - Skirt Trim Kit - Light Commercial
Installation instructions for skirt trim kit for Models R6GF, P6SD, R8GD, R8HE, DF6SF, & R6GI sizes 2-4 tons
Download File
434.5 kB
Option - Installation - Roof Curb - Light Commercial
Roof curb (8", 14", 18", & 24") installation instructions for Models DF6SF, P6SD, Q6SD, R6GD, R6GF, R6GI, & R8GD
Download File
105.8 kB
Option - Installation - Concentric Diffuser - Light Commercial
Concentric diffuser installation instructions for Models P6SD, R6GI, P6SD, Q6SD, R6GD, R8GD, P6SP, Q6SP, R6GP, & R6GN
Download File
457.9 kB
Option - Installation - Horiz. Economizer - Light Commercial
Horizontal, modulating economizer installation instructions for Models P6SD, Q6SD, R6GD, R6GF, & R8GD
Download File
274.0 kB
Option - Installation - CO2 Sensor - Light Commercial
CO2 sensor installation instructions for Models P6SD, P6SP, Q6SP, R6GP, R8GD, Q6SD, & R6GD
Download File
418.9 kB
Option - Installation - Low Ambient Control - Light Commercial
Low ambient control kit installation instructions for Models DF6SF, P6SD, Q6SD, R6GD, R6GF, & R8GD
Download File
60.6 kB
Option - Installation - Filter - Lt Commercial
Filter kit for downflow applications (not required with economizer) kit installation instructions for Models R6GF, R8GD, P6SD, & DF6SF
Download File
169.2 kB
Option - Installation - Smoke Detector - Light Commercial
Smoke detector installation kit installation instructions for Models P6SD, P6SP, R6GP, Q6SD, R8GD, R6GN, R6GD, B5SM, & Q6SP
Download File
274.9 kB
Option - Installation - Horiz. Economizer
Hotizontal economizer installation instructions for 2-5 ton Large Package Units (AC, HP or Gas Electric)
Download File
1.1 MB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
Download File
340.4 kB

Training
1 File

Training


English
Application - Duct Smoke Detectors - Light Commercial
Application guide for using smoke detectors with Models P6SD, P6SP, R6GP, Q6SD, R8GD, R6GN, R6GD, B5SM, & Q6SP
Download File
293.7 kB

Other Files
1 File

Other Files


English
Warranty Statement
Reznor equipment limited warranty statement
Download File
183.4 kB