Single Packaged Gas/Electric Units 20 SEER 81% AFUE Multi-Stage Cool/2-Stage Heat

2 - 5 Ton Single-Phase Units

The iQ Drive® gas/electric package system features modulating compressor technology and variable speed indoor and outdoor fan motors. This system is controlled from a two stage cooling and heating thermostat. The system has the capability of adding up to 18% of additional cooling above the rated capacity. The system has dehumidification capabilities from thethermostat or duct mounted humidistat. These single packaged gas/electrics are ultra-high efficiency self-contained cooling units that can be installed on the roof or on a slab. The convertible unit design makes installations simple in all applications. Units are ETL and ETLc listed.

Heating Range ( MBH )

Cooling Range ( MBH )

Airflow Range ( CFM )

Heating Efficiency at full load ( AFUE )

Cooling Efficiency ( EER )

Standard Features

  • iQ Drive: inverter driven Samsung rotary compressor provides five capacities in modulating operation from a two stage thermostat
  • Interface control board: two digit LED provides system operation, status and diagnostic trouble shooting information. Utilizes a Nordyne-patented capacity control algorithm to select the optimum system capacity level. Internal controls monitor system operation to protect the inverter drive and compressor
  • Cooling operation temperature range of 50° to 125°F
  • Five minute restart time delay keeps the unit from restarting, eliminating the highest cause for compressor failure
  • EXV control: precise refrigerant superheat control provided by an electronic expansion valve
  • Suction accumulator protection from liquid flood back and future compressor failures
  • Compressor and component access is designed to make servicing easier for the contractor, hinge access panel is proved to all controls and the compressor
  • High efficiency with low sound levels: 20 SEER with sound ratings from 63 to 74 db depending upon the operating conditions. Engineered to significantly reduce unwanted noise with compressor sound blanket, variable speed condenser motor and swept-wind fan blade and discharge muffler.
  • High pressure switch protects against abnormally high system pressures. Auto-reset feature prevents nuisance service visits.
  • Low pressure switch protects against loss of system refrigerant charge
  • Liquid line filter dryer
  • Micro-Channel condenser coils: all aluminum coils that provide high corrosion resistance and increased heat transfer
  • Anteater copper tube (Luvata Uniguard) / aluminum fin indoor coils: indoor coils are designed to optimize heat transfer, and increase durability and reliability.
  • Wire guard coated with Earth-friendly epoxy and plastic mesh hail guard will never rust and protects the unit coil from being damaged
  • Designed using galvanized steel with a polyester urethane coat finish. The 950 hour salt spray finish resists corrosion 50% better than comparable units.
  • Heavy-gauge full perimeter base rails facilitate forklift handling and curb mounting
  • Convertible air delivery: horizontal or downflow to accommodate rooftop or horizontal applications
  • Corrosion-resistant drain pan quickly drains away evaporator condensate
  • One piece top for great fit and finish, total seal: well designed, quality construction. Drip edge on top panel whisks away rainwater. Embossed bottom pan keeps blower component compartment dry.
  • SmartLife® Control Board provides extended life to igniters using hot surface ignition technology. Programmed to learn the heat-up characteristics of the igniter, ten adapt the ignition time to the characteristics of the furnace so the igniter is energized appropriately.
  • Hot surface igniter: innovative application of an appliance type igniter with a 20 year history of reliability
  • Energy efficient variable speed ECM blower: advanced motor technology provides 16 fields selectable cooling and 8 for heating. Extra quiet and smooth blower on and off cycles, automatically adjusts to different static loads.

Optional Features - Factory Installed

  • Gasheating section

Optional Features - Field Installed

  • Roof curb (8", 14", 18", or 24")
  • Cap duct adapter
  • LP conversion kit
  • Skirt trim kit
  • Supply/return transitions
  • Concentric diffuser
  • Manual or motorized fresh air damper
  • Hood type hail guard

Brochures
5 Files

Brochures


English
Light Commercial Marketing Catalog
Light Commercial HVAC Equiment Marketing Catalog
Download File
1.0 MB
Comp Edge: R6GI iQ Drive® Gas/Electric Packaged System
Intelligent HVAC, iQ Drive® with SmartLite® Control Boardr6g
Download File
396.6 kB
Energy Edge: 20 SEER Selection Guide
Model R6GI: 20 SEER packaged HVAC system quick selection guide.
Download File
492.9 kB
Energy Edge: Ultra High Efficiency Packaged Systems
Model R6GI: 20 SEER and Model R8HE: 95% gas heating efficiency systems.
Download File
516.5 kB
Heating, Cooling, Ventilation & VRF Product Line
Heating, Cooling, Ventilation & VRF Product Line Sheet
Download File
630.7 kB

Technical Data
1 File

Technical Data


English
Tech Spec - R6GI
Description, options, & dimensions for Model R6GI
Download File
606.0 kB

Service/Installation
13 Files

Service/Installation


English
Unit Installation Manual - R6GI
Installation manual for Model R6GI
Download File
7.3 MB
Option - Installation - Roof Curb - Light Commercial
Roof curb (8", 14", 18", & 24") installation instructions for Models DF6SF, P6SD, Q6SD, R6GD, R6GF, R6GI, & R8GD
Download File
105.8 kB
Option - Installation - Supply/Return Transition - Light Commercial
Supply/return (16" & 18") transition installation instructions for Models P6SD, R6GI, Q6SD, R6GD, & R8GD
Download File
69.0 kB
Option - Installation - Motorized Fresh Air Damper - Light Commercial
Motorized fresh air damper installation instructions  for Models P6SD, Q6SD, R6GD, R6GI, & R8GD
Download File
139.0 kB
Parts Manual - Model R6GI
Model R6GI parts manual
Download File
1.1 MB
Option - Installation - Skirt Trim Kit - Light Commercial
Installation instructions for skirt trim kit for Models R6GF, P6SD, R8GD, R8HE, DF6SF, & R6GI sizes 2-4 tons
Download File
434.5 kB
Option - Installation - Manual Fresh Air Damper - Light Commerical
Manual fresh air damper installation instructions for Models P6SD, Q6SD, R6GD, R6GI, & R8GD
Download File
115.5 kB
Option - Installation - Concentric Diffuser - Light Commercial
Concentric diffuser installation instructions for Models P6SD, R6GI, P6SD, Q6SD, R6GD, R8GD, P6SP, Q6SP, R6GP, & R6GN
Download File
457.9 kB
Option - Installation - Hood Hail Guard - Light Commercial
Hood type hail guard installation instructions for Models Q6SD, P6SD, R6GD, R8GD, & R6GI
Download File
579.0 kB
Wiring Diagram - Model R6GI - 2-4 Tons
Model R6GI 2-4 tons typical wiring diagram
Download File
51.8 kB
Option - Installation - Horiz. Economizer
Hotizontal economizer installation instructions for 2-5 ton Large Package Units (AC, HP or Gas Electric)
Download File
1.1 MB
Wiring Diagram - Model R6GI - 5 Ton
Model R6GI 5 ton typical wiring diagram
Download File
52.6 kB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
Download File
340.4 kB

Other Files
1 File

Other Files


English
Warranty Statement
Reznor equipment limited warranty statement
Download File
183.4 kB