The P7TQ is a next-generation, packaged air conditioner that fits popular existing curbs, eliminating the cost of an adaptor curb.

  • Compatible Connections. Matchbox design to fit on Carrier exisiting curbs and existing bottom gas and electrical connections if required.
  • Easy Installation. Low MCA/MOP so no need to upgrade electrical service in most applications. Unit weight is likely equal to or lower than other products, so no need for structural changes.
  • 1" Foam Panel Wall Construction. No exposed fiberglass insulation in air stream for increased air quality and suppressed mold growth; lower ambient sound.
  • Heavy-Duty Hinged, Foamed Doors. Easy access to blower, controls and filters with no air leaks and no screws to lose.
  • Micro-Channel Coils. All aluminum for high corrosion resistance and increased heat transfer. 1/2 the refrigerant as compared to conventional units.
  • High Efficiency. Uses less grid power. 12.9 IEER, ASHRAE Std. 90.1-2013, California Title 24 Compliant.

Heating Range ( MBH )

Cooling Efficiency ( EER )

Standard Features

  • Easy Control Section Access
  • 208/230, 460 & 575V Power
  • Terminal Wiring Connections
  • Standard Thermostat Connection
  • Replaceable Cube Relays
  • Single Power
  • Four Corner Bottom Lifting Connections

DX SYSTEM

  • High Efficiency 12.7 IEER, meets ASHRAE 90.1-2013
  • R410-A Refrigerant
  • Driers & TXV
  • Easy Access for Inspection & Service
  • Lightweight Micro-Channel Evaporator Coil
  • 1/2 the Refrigerant Use
  • Corrosion Proof Drain Pain

HEAT SECTION

  • Life Off Door for easy service to DX, Gas & Electric Heat Section
  • Bottom Gas & Electrical Connections (Matches Carrier Connections)
  • 1" Gas Connection (bottom connection available)
  • Gas Flue Hood (R7TQ model)

CONDENSER

  • Low Noise Condenser Fans
  • Low Ambient (32F)
  • Lighweight Micro-Channel Coils
  • Less Refrigerant Charge

CONSTRUCTION

  • 1" Foam Panel Contruction Roof, Walls & Base
  • R-6.4 Insulation
  • Base Unit Fits on Existing Carrier Curb
  • Fork Life Access from 3 Sides
  • 8", 14", 18" & 24" Roof Curbs
  • Single Power Connection
  • Water Tight (gasket) Hinged Access Doors
  • Heavy Duty Latches & Hinges

BLOWER SECTION

  • Forward Curve Blower
  • High Static Drive Options, 1.0" wc E.S.P.

AIR MANAGEMENT

  • Field Convertible Horizontal Supply & Return - Panels replace vertical holes
  • Enhanced Security Burglar Bars (Return & Supply Access available)
  • Filtered MERV 5) & Hooded Intake
  • ASHRAE Std 90.1-2013 Compliant

Available Features

  • Unit Mounted Disconnect
  • Low, Medium & High Gas Heat
  • 304 Stainless Steel Heat Exchanger
  • High Altitude & Propane Conversion Kits

DX SYSTEM

  • Suc Press Cutout
  • Overflow Alarm Switch
  • Coil Frost Protection

HEAT SECTION

  • Flue Extension Kit (R7TQ model)

CONDENSER

  • Coil Coating 6000> Salt Hours
  • Mesh Hail Guard
  • Hood Hail Guard

CONSTRUCTION

  • Convenience Outlet
  • Full Unit crating
  • Flatbed and LTI crating
  • MERV 4 & 8 Filters

BLOWER SECTION

  • ECM Motor
  • Smoke Detector

AIR MANAGEMENT

  • CO2 Demand Control

Field Installed

CONSTRUCTION

  • Electrical heat

Field or Factory Installed

AIR MANAGEMENT

  • Economizer Title 24 Compliant with Filtered Outdoor Air
  • 2 Position Manual & Motorized Outdoor Air Intake

Factory Installed Options

  • Stainless Steel Heat Exchanger
  • Coated Condenser Coil for costal applications
  • 2" MERVE 8 Pleated filters
  • Mesh Hail Guard
  • Hooded Hail Guard
  • Manual OA Damper & Hood
  • Motorized OA Damper & Hood
  • Economizer, Enthalpy control and CA Title 24
  • CO2 Sensor, wall or duct mounted
  • Drain Pan Condensate Float Switch
  • Low Suction Pressure Cutout Switch
  • Coil Freeze stat
  • Low Ambient Cooling Operation down to 32F
  • Photoelectric Smoke Detector
  • Convenience Outlet
  • Disconnect Switch

Field Installed Options

  • LP Gas Conversion Kit
  • High Altitude Conversion
  • Flue Exhaust Extension Kit
  • Burglar Bars - Return & Supply Duct Access
  • Roof Curbs, 8", 14", 18" & 24"
  • Extreme Wind Kit

Brochures
2 Files

Brochures


English
Light Commercial Packaged Rooftops Brochure
Configurable (R,P)7TQ packaged rooftop units
Download File
354.7 kB
Heating, Cooling, Ventilation & VRF Product Line
Heating, Cooling, Ventilation & VRF Product Line Sheet
Download File
630.7 kB

Technical Data
1 File

Technical Data


English
Tech Spec - P7TQ
Description, options, & dimensions for Model P7TQ
Download File
639.6 kB

Service/Installation
23 Files

Service/Installation


English
Replacement Parts List - P7TQ Series
Replacement Parts List - Packaged AC Unit with Optional Electric Heat - P7TQ Series
Download File
1.1 MB
Option - Installation - Power Exhaust Kit - R7TQ, P7TQ, Q7TQ
Power exhaust kit installation instructions for models R7TQ, P7TQ, and Q7TQ
Download File
1,003.4 kB
Wiring Diagram - Model P7TQ 150
Wiring Diagram for Model P7TQ-150 - sheet 1
Download File
320.7 kB
Installation Instructions - R7TQ/P7TQ/Q7TQ
Installation Instructions for R7TQ/P7TQ/Q7TQ - 090 and -120 Series - 3 HP ECM Motor / Controller High Static Drive Kits
Download File
616.4 kB
User's Manual - P7TQ / Q7TQ / R7TQ
User's Manual for P7TQ, Q7TQ and R7TQ
Download File
911.9 kB
Wiring Diagram - Model P7TQ 72 - 460 Volts
Wiring Diagram for R7TQ 72 series, 2-Speed Motor, 460 Volts
Download File
246.0 kB
Wiring Diagram - Model P7TQ 72 - ECM Motor
Wiring Diagram for R7TQ 72 series, ECM Motor, 208-240 Volts
Download File
224.2 kB
Wiring Diagram - Model P7TQ 72 - ECM Motor - 575 Volts
Wiring Diagram for P7TQ 72 series - ECM Motor - 575 Volts
Download File
215.7 kB
Wiring Diagram - Model P7TQ 90/120 - 460 Volts
Wiring Diagram for P7TQ 90/120 series - 2-Speed Motor - 460 Volts
Download File
250.7 kB
Wiring Diagram - Model P7TQ 90/120 - ECM Motor
Wiring Diagram for P7TQ 90/120 series - ECM Motor - 208-240 Volts
Download File
249.5 kB
Wiring Diagram - Model P7TQ 90/120 - 575 Volts
Wiring Diagram for P7TQ 90/120 series - ECM Motor - 575 Volts
Download File
245.2 kB
Unit Installation Manual - P7TQ
Installation manual Model P7TQ
Download File
4.7 MB
Wiring Diagram - Models R7TQ, P7TQ & Q7TQ
Wiring diagram for R7TQ, P7TQ & Q7TQ - 208-230/460 Volt
Download File
52.2 kB
Wiring Diagram - Model P7TQ-150
Wiring Diagram for Model P7TQ-150 - sheet 2
Download File
319.0 kB
Heater Kit Installation - P7TQ and R7TQ
Instructions for installing H9HK series heater kit
Download File
1.1 MB
Wiring Diagram - Model P7TQ 72
Wiring Diagram for P7TQ 72 series, 2-Speed Motor, 208-240 Volts
Download File
247.6 kB
Wiring Diagram - Model P7TQ 72 - 575 Volts
Wiring Diagram for R7TQ 72 series, 2-Speed Motor, 575 Volts
Download File
243.3 kB
Wiring Diagram - Model P7TQ 72 - ECM Motor - 460 Volts
Wiring Diagram for P7TQ 72 series - ECM Motor - 460 Volts
Download File
219.7 kB
Wiring Diagram - Model P7TQ 90/120
Wiring Diagram for P7TQ 90/120 series - 2-Speed Motor - 208-240 Volts
Download File
252.0 kB
Wiring Diagram - Model P7TQ 90/120 - 575 Volts
Wiring Diagram for P7TQ 90/120 series - 2-Speed Motor - 575 Volts
Download File
246.5 kB
Wiring Diagram - Model P7TQ 90/120 - ECM Motor - 460 Volts
Wiring Diagram for P7TQ 90/120 series - ECM Motor - 460 Volts
Download File
246.2 kB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
Download File
340.4 kB
Français
Notice D'Installation - P7TQ
Série P7TQ- 072 / 090 / 120 / 150. Appareils monoblocs de chauffage / climatisation électrique de toit.
Download File
4.7 MB

Other Files
1 File

Other Files


English
Warranty Statement
Reznor equipment limited warranty statement
Download File
183.4 kB