Model YDHA space conditioning unit provides superior control of high volumes of outside air in a packaged DX system design. The model’s feature set allows it to properly condition upward to 50% outside air while maintaining space temperature and humidity conditions. The unit’s blower system incorporates superior energy efficient blower design with variable speed control to balance and control the airflow as needed. The DX system maximizes efficiency with the use of digital scroll technology, ECM condenser fans and optimized coil designs. The DX system exceeds ASHRAE standard 90.1 requirements. Model YDHA includes the Tcore3 condensing heat technology. Tcore3 condensing gas heating system maintains greater than 90% efficiency throughout the modulated control range. The system features state of the art stand alone control system that further maximizes energy use while maintaining space temperature condition.

Capacité de chauffe ( MBH )

Capacité de refroidissement ( MBH )

Débit d'air ( CFM )

Rendement à pleine charge ( PCS )

Supply & Exhaust Fan

  • 750 - 10,500 SCFM Direct drive backward incline plenum fan
  • High external static pressure capability
  • Factory installed ABB variable frequency drive
  • Easy CFM verification for all fans

Mechanical Cooling

  • R410A refrigerant (environmentally friendly)
  • High efficiency digital scroll technology 10-100% capacity control
  • Fully interlaced coils
  • Compressor anti-cycle programming
  • Mechanical gauge connections
  • High & low pressure switches
  • Crank case heaters
  • Anti-rust, dual sloped condensate drain pan
  • Froststat, all circuits

Gas Heating

  • Natural gas or propane furnace
  • Patented Tcore3 combustion control (patent # 8,113,269)
  • High capacity heat for colder climates
  • Minimum 80% thermal efficiency (Std)
  • 409 stainless steel heat exchanger
  • Failure/alarm diagnostics

Electric Heat

  • High capacity heat for colder climates
  • Failure/alarm diagnostics

Construction

  • Double wall foam panel construction – R12
  • Hinged access doors with slam latches
  • G90 Galvanized Steel Substrate, 60 Gloss Finish
  • Convenient single door access panel for all controls, heating, and cooling sections)
  • 4 point bottom lifting
  • 4” pleated MERV 8 filters
  • Vertical discharge, roof or pad mounting
  • Full perimeter curbs

Controls

  • Single point power connections
  • Isolated high voltage compartment
  • ABB patented high voltage management system
  • DDC unit controller output
  • LED status
  • Unit mounted display
  • Easy unit & sequence configuration
  • Unit alarm logging and retrieval
  • Unit sensor and command values trending for retrieval
  • Easy unit functional test mode

Brochures
8 Fichiers

Brochures


English
Patented Hot Gas Reheat Circuit – R7DA, YDMA & YDHA Models
Patented Hot Gas Reheat Circuit – R7DA, YDMA & YDHA Models
Télécharger fichier
455.9 kB
YDHA Marketing Catalog
Model YDHA Marketing Catalog
Télécharger fichier
693.0 kB
Comp Edge: P125 Rooftop Unit
The "Reznor Edge" or advantages in using one of the packaged HVAC units in the Platform 125 series. Each offers different benefits to meet a wide variety of application needs.
Télécharger fichier
584.2 kB
Comp Edge: Superior Dehumidification with ReHeat Pump™
Advantages of using a ReHeat Pump vs. a hot gas reheat (HGRH) system
Télécharger fichier
404.7 kB
Comp Edge: Model YDHA
Features, benefits and advantages of using Model YDHA Packaged RTU system for up to 50% outside air applications.
Télécharger fichier
269.1 kB
Comp Edge: P125 Series Built-to-Last Solid Construction
The P125 Series is design engineered for long-lasting operation.
Télécharger fichier
245.1 kB
Energy Edge: Condensing Gas Heating (90%+ Efficient)
No matter what region you are in North America, Heating makes up the majority of the average building energy usage. By using Reznor condensing gas heating equipment (over 90% fuel efficient), you can make a big impact on the overall utility bills.
Télécharger fichier
404.4 kB
Heating, Cooling, Ventilation & VRF Product Line
Heating, Cooling, Ventilation & VRF Product Line Sheet
Télécharger fichier
630.7 kB

Données Techniques
2 Fichiers

Données Techniques


English
Catalog - Rooftop Units
Rooftop unit catalog for Models YDHA & YDMA
Télécharger fichier
3.8 MB
Sample Specs - YDHA
Sample specifications for Model YDHA (Word document)
Télécharger fichier
53.8 kB

Service / Installation
10 Fichiers

Service / Installation


Français
Instructions D'Installation - Modèle YDHA, YDMA, et YDSA
Installation modèles YDHA, YDMA et YDSA
Télécharger fichier
8.4 MB
English
Unit Installation Manual - YDHA, YDMA, & YDSA
Installation manual for Platform 125 Models YDHA, YDMA, and YDSA
Télécharger fichier
8.0 MB
Operation Manual for YDMA, YDHA, YDSA
Operation, maintenance and service manual for Models YDMA, YDHA, & YDSA in Platform 125
Télécharger fichier
5.2 MB
Parts Manual - Models YDHA, YDMA, & YDSA
Parts manual for P125 series - Models YDHA, YDMA, & YDSA
Télécharger fichier
9.6 MB
Option - Installation - Weather Hood Assembly
Instructions for installing a weather hood for Models ADF, ADFH, RCB, RDB, RDCB, RDDB, RECB, REDB, RCC, RDC, RDCC, RDDC, RECC, REDC, RPB, RPBL, RBL, YDHA, YDMA, and YDSA
Télécharger fichier
814.5 kB
Option - Installation - Roof Curbs Assembly
Instructions for installing roof curb for various models
Télécharger fichier
1.6 MB
Option - Installation - Power Exhaust Kit - YDMA, YDHA
Power exhaust kit installation instructions for models YDMA and YDHA
Télécharger fichier
442.4 kB
Controls - R7DA, YDHA, YDMA, and YDSA models
Controls manual for P125 (YDHA, YDMA, and YDSA) and R7DA models
Télécharger fichier
1.1 MB
Option - Installation - High-Wind Kit
High-Wind Kit Installation Instructions for P125 series: Models YDHA, YDMA, and YDSA
Télécharger fichier
2.5 MB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
Télécharger fichier
340.4 kB

Autres Fichiers
1 Fichier

Autres Fichiers


English
Warranty Statement
Reznor equipment limited warranty statement
Télécharger fichier
183.4 kB

Factory Bulletin : R20-103 : Strategic Importance of Dedicated Outdoor Air Systems (DOAS)

Strategic Importance of Dedicated Outdoor Air Systems (DOAS) in Controlling Disease Transmission.

Lire plus...