Média

DF6SF
DF6SF


Description

2-Stage Heat/2-Stage Cool with Variable Speed Blower
iHybrid™ Dual Fuel Package Units

15 SEER (2 - 5 Tons)

These dual fuel package units are high efficiency self contained heat pump units that can be installed on the roof or on a slab. The convertible unit design makes installations simple in all applications. Units are ETL and ETLc listed.

Capacité de chauffe ( MBH )

Capacité de refroidissement ( MBH )

Débit d'air ( CFM )

Rendement à pleine charge ( HSPF )

Cote d’efficacité énergétique ( EER )

Standard Features

  • Copeland Ultra-Tech Scroll Compressor: State of the art 2 stage compressor is standard equipment.
  • Quiet Operation and Low Vibration: Swept-wing fan blade combined with custom Venturi condenser fan.
  • Compressor Sound Blanket
  • Wire guard coated with Earth Friendly Epoxy and plastic mesh hail guard: A guard that will never rust and protects the units coil from being damaged.
  • Anteater Evaporator Coil: For increased resistance against formicary corrosion, the number one cause of evaporator coil failures.
  • Designed using Galvanized Steel: With a polyester urethane coat finish. The 950 hour salt spray finish is 1.5 mil thick and resists corrosion 50% better than comparable units.
  • Smaller Panels, Great Fit and Finish, Total Seal: Well-designed, quality construction.
  • One Piece Top Pan: With drip edge on top panels whisks away rainwater.
  • Embossed bottom pan: Keeps blower component compartment dry.
  • Permanently Lubricated Condenser Motor: A heavy duty PSC motor for long lasting reliability and quiet operation. Requires no maintenance and is completely protected from rain and snow.
  • Thermostatic Expansion Valves: Factory installed externally equalized thermostatic expansion valves provides precise refrigerant control under varying load conditions.
  • Hi/Low Pressure Switches: Ensure long compressor life.
  • Externally Accessible, High Flow Service Ports: Quick access to refrigeration system.
  • Liquid Line Filter Driers: Factory installed at a convenient location for service.
  • Suction Accumulator: Protection from liquid flood back and future compressor failures.
  • Low voltage Transformer: Includes 5 Amp fuse to protect low voltage circuit.
  • Corrosion-Resistant Drain Pan: Quickly drains away evaporator condensate.
  • ECM Variable Speed Blower Motor: Advanced technology allows the motor to automatically adjust to different static loads. The variable speed motor allows for extra quiet operation and improved air quality.
  • Demand Defrost Standard: Provides additional energy savings in heating by defrosting only when necessary.
  • Three Minute Restart Time Delay: When the unit shuts down, a three minute delay keeps the unit from restarting, eliminating the highest cause for compressor failure.
  • Heavy-Gauge, Full Perimeter Base Rails: Facilitates forklift handling and curb mounting.
  • Convertible Air Delivery: Horizontal or downflow to accommodate rooftop or horizontal applications.
  • Easy Compressor and Control Access: Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit.
  • Removable Top Grille Assembly: Allows ease of service to the fan motor.
  • Duct Flanges: Reduce installation costs.
  • Proven, Industry Standard Components: Easier service and availability.
  • SmartLite™ Control Board: Provides extended life to igniters using hot surface ignition technology. Programmed to learn the heat-up characteristics of the igniter, then adapt the ignition time to the characteristics of the furnace so the igniter is energized appropriately.

Optional Features - Factory Installed

  • 2-Stage Gas Heat Operation: Featuring a 2 stage gas valve and 2 speed inducer motor.
  • Choice of Heating Control: Two stage thermostat or single stage heating thermostat with on the control board timing of 5 or 10 minute delay for second stage of heat.

Optional Features - Field Installed

  • Cap duct adapter
  • Low ambient kit
  • LP conversion kit
  • Universal hard start kit
  • Thermostat with backup gas heat capability (outdoor sensor required)
  • Thermostat - outdoor sensor
  • Skirt trim kit

Brochures
2 Fichiers

Brochures


English
Light Commercial Marketing Catalog
Light Commercial HVAC Equiment Marketing Catalog
Télécharger fichier
1.0 MB
Heating, Cooling, Ventilation & VRF Product Line
Heating, Cooling, Ventilation & VRF Product Line Sheet
Télécharger fichier
630.7 kB

Données Techniques
1 Fichier

Données Techniques


English
Tech Spec - DF6SF
Descriptions, options, dimensions for Model DF6SF
Télécharger fichier
923.6 kB

Service / Installation
12 Fichiers

Service / Installation


English
Unit Installation Manual - DF6SF
Installation manual for Model DF6SF
Télécharger fichier
4.1 MB
Option - Installation - Roof Curb - Light Commercial
Roof curb (8", 14", 18", & 24") installation instructions for Models DF6SF, P6SD, Q6SD, R6GD, R6GF, R6GI, & R8GD
Télécharger fichier
105.8 kB
Option - Installation - Low Ambient Control - Light Commercial
Low ambient control kit installation instructions for Models DF6SF, P6SD, Q6SD, R6GD, R6GF, & R8GD
Télécharger fichier
60.6 kB
Option - Installation - Filter - Lt Commercial
Filter kit for downflow applications (not required with economizer) kit installation instructions for Models R6GF, R8GD, P6SD, & DF6SF
Télécharger fichier
169.2 kB
Parts Manual - Model DF6SF
Model DF6SF parts manual
Télécharger fichier
1.0 MB
Option - Installation - Skirt Trim Kit - Light Commercial
Installation instructions for skirt trim kit for Models R6GF, P6SD, R8GD, R8HE, DF6SF, & R6GI sizes 2-4 tons
Télécharger fichier
434.5 kB
Option - Installation - Filter Kit - Light Commercial
Filter kit installation manual for for Models R8GD, P6SD, DF6SF, R6GF, & R8GD
Télécharger fichier
323.0 kB
Option - Installation - Hard Start - Light Commercial
Universal hard start kit installation instructions for Models JS4BD, JT4BD, P6SD, DF6SF, R8GD, R6GF, R8HE
Télécharger fichier
263.4 kB
Wiring Diagram - Model DF6SF
Model DF6SF typical wiring diagram
Télécharger fichier
42.7 kB
Option - Installation - Horiz. Economizer
Hotizontal economizer installation instructions for 2-5 ton Large Package Units (AC, HP or Gas Electric)
Télécharger fichier
1.1 MB
Wiring Diagram - Model DF6SF w/Comfort Alert
Model DF6SF with Comfort Alert™ Diagnostic Controller typical wiring diagram
Télécharger fichier
131.6 kB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
Télécharger fichier
340.4 kB

Autres Fichiers
1 Fichier

Autres Fichiers


English
Warranty Statement
Reznor equipment limited warranty statement
Télécharger fichier
183.4 kB