Prodotti Aerotermi F

Media

F
F
F Installation
F Installation


Descrizione

Reznor's F gas-fired, gravity-vented unit heaters are designed for ceiling suspension with a propeller fan for air delivery with 80% thermal efficiency. It may be used with natural or propane gas, as specified, in sizes from 25,000 to 400,000 BTUH gas input. These units are approved for installation in the United States and Canada by the Canadian Standards Association(CSA).

 

Notes:

  • Model F units require the addition of spark pilot option AH2 or AH3.
  • Not certified for residential use.

Capacità di riscaldamento ( MBH )

Campo di portata d'aria ( CFM )

Freccia d'aria ( Feet )

Rendimento termico (carico massimo) ( Gross )

Standard

  • Orifices for natural gas
  • Aluminized steel heat exchanger
  • Aluminized steel burner rack with stainless steel insert
  • Spark ignited pilot
  • Intermittent safety pilot with electronic flame supervision without timed lockout
  • Single-stage combination gas valve (field adjustable for high altitude operation)
  • 115/1/60 supply voltage
  • 115 volt fan motor with internal overload protection
  • Fan and limit safety controls
  • Energy cutoff (ECO) device
  • Blocked vent shutoff system
  • 24-volt control voltage transformer
  • Individually adjustable horizontal louvers
  • Full safety fan guard
  • Terminal strip connector for 24-volt field wiring
  • Convenient bottom burner access
  • 2-point 3/8"-16 threaded hanger connections
  • Horizontal/vertical vent outlet

Optional Features - Factory Installed:

  • Equipped for propane gas
  • Equipped for high altitude (2001-9000 ft)
  • E-3 (409) stainless steel heat exchanger and burner
  • Two-stage gas control (50% low fire) - sizes 75-400
  • Spark ignited, intermittent safety pilot with electronic flame supervision with or without timed lockout (timed lockout is required for propane gas)
  • Manual summer/winter switch
  • Burner air shutters
  • 220/240 volt/50 Hertz electrical operation
  • Totally enclosed 115V motor
  • Low ambient fan control relay

Optional Features - Field Installed:

  • Power venter
  • Vertical louvers
  • Downturn air nozzle, 25-65o or 50-90o variable air deflector range (includes 4-point suspension kit)
  • Thermostat and relay kits
  • Air recirculation kits
  • Manual summer/winter switch
  • Multiple heater control
  • 4-point suspension kit
  • Unit-mounted thermostat bracket
  • Step down transformer 230/115 or 460/115
  • Burner air shutters
  • Low ambient fan control relay kit
  • Hanger kit to suspend from 1" pipe (2 or 4 point suspension)
  • Single-stage and two-stage thermostats
  • Thermostat guard with locking cover
  • Manual shutoff valve and union
  • Gas conversion kit

Brochure
2 Files

Brochure


English
Comp Edge: With over 70 years of production, Reznor Unit Heaters are the proven leader in the industry
Comp Edge: With over 70 years of production, Reznor Unit Heaters are the proven leader in the industry
Scaricare il file
278.0 kB
Heating, Cooling, Ventilation & VRF Product Line
Heating, Cooling, Ventilation & VRF Product Line Sheet
Scaricare il file
630.7 kB

Dati Tecnici
2 Files

Dati Tecnici


English
Catalog - Unit Heater
Unit heater catalog
Scaricare il file
4.5 MB
Submittal - Options - Unit Heater
Options available for gas fired unit heaters
Scaricare il file
1.0 MB

Servizio / Installazione
27 Files

Servizio / Installazione


English
Unit Installation Manual - F & B
Installation manual for Models F & B
Scaricare il file
1.5 MB
Parts Manuals - F & B
Parts manual for Models F & B (and discontinued Models FE & BE)
Scaricare il file
822.9 kB
Option - Installation - Thermostat Bracket (Unit Mounted) Assembly
Instructions for installing a unit mounted thermostat bracket
Scaricare il file
304.1 kB
Option - Installation - Horizontal/Vertical Vent Outlet Instructions, size 125
Instructions for required field assembly of vent outlet for Models F & B in size 125
Scaricare il file
116.7 kB
Option - Installation - Burner Air Shutters Installation - Models F & B
Instructions for installing burner air shutters for Models F & B
Scaricare il file
417.9 kB
Option - Installation - Low Ambient Control Relay Installation - Models F & B
Instructions for installing low ambient control relay for Models F & B
Scaricare il file
465.9 kB
Option - Installation - Relay & Thermostats Installation - Models F & B
Instructions for installing relay and/or thermostat for Models F & B
Scaricare il file
217.0 kB
Option - Installation - Stepdown Transformer Installation - Models F & B
Instructions for installing a stepdown transformer for Models F & B
Scaricare il file
231.2 kB
Option - Installation - Hanger Kit Installation - Unit Heaters
Instructions for installing an optional hanger kit
Scaricare il file
354.1 kB
Option - Installation - Horizontal/Vertical Vent Outlet Instructions sizes 250, 300 & 400
Instructions for assembly of required vent outlet for Models F & B in sizes 250, 300 & 400
Scaricare il file
113.1 kB
Option - Installation - Downturn Nozzle Installation - Models F & B
Instructions for installing the downturn nozzle for Models F & B
Scaricare il file
454.5 kB
Option - Installation - Power Venter Installation - Models F & B
Instructions for installing field supplied power venter for Models F & B
Scaricare il file
678.9 kB
Option - Installation - Vertical Louvers Installation - Models F & B
Instructions for installing vertical louvers for Models F & B
Scaricare il file
205.1 kB
Option - Installation - Fan Switch Installation - Model F
Instructions for installing a manual summer/winter fan switch on Model F
Scaricare il file
269.3 kB
Option - Installation - Multiple Heater Control Installation
Installation instructions for multiple heater control system
Scaricare il file
479.1 kB
Parts Manuals - Functional Replacement Fan/Blower Controls and Limit Controls
 Parts manual for functional replacement fan/blower controls and limit controls
Scaricare il file
322.8 kB
Parts Manuals - Pilots - Parts manual
Functional replacement pilots
Scaricare il file
394.4 kB
Conversion Info - Gas Conversion - Model F, B
Gas conversion kit and instructions for Models F & B
Scaricare il file
308.1 kB
Parts Manuals - Replacement Ignition System and Gas Valves
Replacement ignition system and gas valves by serial number code and Maxitrol system components by serial number suffix
Scaricare il file
1.3 MB
Conversion Info - Ignition Conversion Kit - Models F, B
Ignition conversion kits to convert older Model F & B heaters with standing pilot to spark-ignited, intermitten safety pilot with or without lockout
Scaricare il file
418.8 kB
Field Service - Ignition Control Replacement - Various Models
Ignition control replacement kit for pilot code 62, 63, 65, 66, & 84 (found in first set of digitis of serial number)
Scaricare il file
250.4 kB
Option - Installation - Valve Kit - M8, U8, U9
Replacement kit for propane valve with serial number code M8, U8, or U9
Scaricare il file
127.1 kB
Conversion Info - Install Re-Designed Burner Rack Support
Installation instructions for re-designed burner rack support included in replacement heat exchanger for Models F, B, FE, & BE
Scaricare il file
65.7 kB
Field Service - Replacement Relay Kit - PN 259521
Replacement relay kit for Reznor part number 259521 - applies to power vented units using Reznor part number 46233 or 259518 time delay relay
Scaricare il file
646.2 kB
Option - Installation - Valve Kit - M6
Replacement kit for natural gas valve with code M6
Scaricare il file
120.5 kB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
Scaricare il file
340.4 kB
Français
Unité manuel d'installation - F et B
Installation, opération et entretien - Modèles F et B
Scaricare il file
2.3 MB

Altri File
1 File

Altri File


English
Warranty Statement
Reznor equipment limited warranty statement
Scaricare il file
183.4 kB