Мультимедиа

RCC
RCC
RCC without ERM
with ERM
RCC with ERM
Energy Recovery Module
Energy Recovery Module
Energy Recovery Module
Energy Recovery Module
Hail Guard


Описание

Reznor's RCC (MAPS®IV) packaged rooftop units are designed to cool high volumes of outside air year-round for makeup air and ventilation applications. In addition, MAPSIV can provide significant capacities of space conditioning.  Model RCC units are designed to provide an average cooling supply air temperature of 50° to 55°F in humid to temperate climates.

All MAPSIV products feature the Reznor IQ digital controller to fully integrate all operation and external sensing into a stand-alone package or through native BacNet®, into a building management system.

Диапазон охлаждения ( MBH )

Диапазон расхода воздуха ( CFM )

Standard

Supply Fan

  • 1,000 - 9,000 CFM
  • Forward Curve Blowers
  • Belt Driven, Adjustable Sheave System
  • Horizontal or Vertical Discharge
  • Vibration Isolated Fan and Motor System
  • Fan and Motor Lube Lines for Servicing
  • Power Exhaust


Mechanical Cooling

  • R410A Refrigerant (Environmentally Friendly)
  • High Outside Air Applications
  • 10% - 100% Capacity Control
  • Modulated Capacity Scroll Compressor with internal motor overload
  • Compressor Anti-Cycle Programming
  • Mechanical Gauge Connections
  • Fully Interlaced Coils

Construction

  • Double Wall Construction Standard - R7 or higher value
  • Hinged Access Doors with Handles
  • Easy Access Compressor Section
  • Filters (MERV8 minimum)
  • Slide out and Sloped Stainless Steel Condensate Drain Pan
  • 4 - 6 Point Base Lifting Connections
  • G90 Galvanized Steel Substrate, 60 Gloss Finish
  • Hold Door Open Service Hinges

Controls

  • Isolated High Voltage Compartment
  • Controller Output LED Status
  • Test Mode
  • Field Selectable Unit Configuration and Unit Mounted Display

Supply Fan

  • Horizontal or Vertical Discharge
  • Optional Unit or Field Mounted VFD
    • Duct Static Pressure Control
    • CO2 Control
    • Building Static Pressure Control
  • Power Exhaust


Mechanical Cooling

  • Corrosion Resistant Coil Coatings

Construction

  • Unit or Field Mounted Disconnects
  • 2” or 4” Permanent or Pleated Filters (MERV8 or MERV13 available)
  • Optional Hail Guard
  • Insulated, 16 Gauge, Downturn or Horizontal air Flow, Full Perimeter Curb

Controls

  • Voltages: 208/3, 230/3, 460/3, 575/3
  • Optional Remote User Display
  • Optional Phase Loss, Smoke Detector, Filter Status
  • Optional Weatherproof Convenience Power Outlet

Intake

  • 100% Outside Air Option
  • 100% Outside & Return Air Option
    • Economizer control
    • CO2 Control
    • Building Static Pressure Control
    • Manual Positioning External 0-10V Signal
  • Optional Outside Air Hood with Washable 1” Filter
  • Integral Energy Recovery Option
    • Variable Flow Control
    • Frost Control
    • Single Curb
    • Isolation Dampers

Warranty

  • Optional Five (5) Year Compressor Warranty

 


брошюры
4 Файлы

брошюры


English
Heating/Cooling Makeup Air Unit Marketing Catalog
Heating/Cooling Makeup Air Unit Marketing Catalog
скачать файл
754.3 kB
Comp Edge: The advantages of using MAPS units
Competitive Edge: The advantages of using MAPS units in different environments and the range of configurations for any zone
скачать файл
408.7 kB
Support Edge: Reznor MAPS equipment start-up assistance
Support Edge: Reznor MAPS equipment start-up assistance
скачать файл
305.1 kB
Heating, Cooling, Ventilation & VRF Product Line
Heating, Cooling, Ventilation & VRF Product Line Sheet
скачать файл
630.7 kB

технические данные
2 Файлы

технические данные


English
Catalog - MAPS®
Modular Air Procesing System (MAPS) catalog for MAPS-III & MAPS- IV Series
скачать файл
5.3 MB
Sample Specs - MAPS®
Sample specifications for Modular Air Processing System (MAPS) Series (Word document)
скачать файл
174.5 kB

Услуги / Монтаж
10 Файлы

Услуги / Монтаж


English
Unit Installation Manual - MAPSIII & MAPSIV
Installation manual for Models RCB, RDB, RCC, RDC, RDCB, RDDB, RDCC, RDDC, RECB, REDB, RECC, & REDC
скачать файл
8.9 MB
Parts Manuals - MAPSIII&IV
Parts manual for MAPSIII (Models RCB, RDB, RDCB, RDDB, RECB, & REDB) & MAPSIV (Models RCC, RDC, RDCC, RDDC, RECC, & REDC)
скачать файл
16.2 MB
Option - Installation - Energy Recovery Module Installation - MAPS III & IV
Instructions for installing an energy recovery module on a MAPS III or MAPS IV system
скачать файл
1.6 MB
Option - Installation - Roof Curbs Assembly
Instructions for installing roof curb for various models
скачать файл
1.6 MB
Option - Installation - Weather Hood Assembly
Instructions for installing a weather hood for Models ADF, ADFH, RCB, RDB, RDCB, RDDB, RECB, REDB, RCC, RDC, RDCC, RDDC, RECC, REDC, RPB, RPBL, RBL, YDHA, YDMA, and YDSA
скачать файл
814.5 kB
Option RB5 - Installation - Remote Display
Installation instructions for optional remote mounted display for PreevA & MAPS Series, and Model ZQYRA
скачать файл
335.8 kB
Controls - IQ System Technical Guide - MAPSIII & IV
IQ system technical guide for control options D15, D16, D17, & D18 for Models RCB, RDB, RDCB, RDDB, RECB, & REDB manufactured since March of 2010 (Serial number code BJC and higher), and for Models RCC, RDC, RDCC, RDDC, RECC, & REDC - Applies to IQ Controller with Version 2 Software
скачать файл
1.7 MB
Operation - MAPS - A,B,C
Operation, maintenance and service manual for MAPSIII & MAPS IV units in cabinet sizes A, B, & C for Models RCB, RDB, RDCB, RDDB, RECB, REDB, RCC, RDC, RDCC, RDDC, RECC, REDC
скачать файл
6.0 MB
Field Service - Damper Motor Replacement
Instructions for replacement kit (261697) for Belimo damper motor
скачать файл
161.8 kB
Field Service - Replacement of Discontinued Relays
Installation for kits designed to replace relays no longer available from suppliers. Applies to all Reznor units using obsolete relays.
скачать файл
340.4 kB

Другие файлы
1 Файл

Другие файлы


English
Warranty Statement
Reznor equipment limited warranty statement
скачать файл
183.4 kB